Temperature Swing Adsorption dryers are dryers that use high temperature to regenerate one of their columns that has been saturated with humidity due to adsorption process. Although our standard is around +160°C, the temperature level depends on the required pressure dew point, adsorbent used, inlet gas composition and other aspects of the process.

R Dry 10000 BVL
The regeneration phase has two major steps, which can be called Heating and Cooling. 

The Heating phase will always use the same principle: some heated gas is blown into the saturated column, most of the time at atmospheric pressure. 

But what sets apart one model from another is the cooling phase, whether it is performed from ambient air (BVA), with cooling water (BVL), with a fraction of the inlet gas (BP, HP) or directly from the compressor's heat (RC-F, RC-P). 

Those differences are schematized below, where we described each type of dryer we can propose, for any gas, any working conditions, any project you might have:

BVA

- Application(s): General industry 
- Climate zone(s): Cold or mild  
- Utilitie(s): Electricity 
- Inlet gas consumption: 0%  
- Features: 
  - Standard version 
  - Good Energy Efficiency ratio

BVA

BP 

- Application(s): General industry 
- Climate zone(s): all 
- Utilitie(s): Electricity 
- Inlet gas consumption: 1-5% in average, depending on conditions 
- Features: 
  - Stable dew point (no water input during cooling, desorption in counter current) 
  - Low power consumption 

BP DRY

BVL

- Application(s): Low dew point applications such as Food & Beverage, Laboratories, Medical equipment, etc… 
- Climate zone(s): all 
- Utilitie(s): Electricity, Water 
- Inlet gas consumption: 0%  
- Features: 
  - Independent from ambient temperature
  - Stable & low water temperature = stable & low dew point 

BVL

RC-F (Full stream)

- Application(s): High temperature oil-free compressors 
- Climate zone(s): all 
- Utilitie(s): Electricity, Water 
- Inlet gas consumption: 0%  
- Features: 
  - Very low power consumption (no heater) 
  - Independent from ambient temperatures

RC DRY

RC-P (Partial stream)

- Application(s): Medium to high temperature oil-free compressors 
- Climate zone(s): all 
- Utilitie(s): Electricity, Water 
- Inlet gas consumption: 0%  
- Features: 
  - Low power consumption 
  - Independent from ambient temperatures

RC P

HP 

- Application(s): 
  - Food & Beverage, Laboratories, Medical equipment, etc… 
  - Flamable and explosive gases  
- Climate zone(s): all 
- Utilitie(s): Electricity, instrument gas in case of external source of regeneration gas, inert gas in case of dangerous gas 
- Inlet gas consumption: 10-15%, depending on conditions  
- Features: 
  - Low dew point 
  - No inlet gas contamination (in case of no external source of regeneration gas used) 

HP

FCL 

- Application(s): 
  - Food & Beverage, Laboratories, Medical equipment, etc… 
  - Flamable and explosive gases  
- Climate zone(s): all 
- Utilitie(s): Electricity, Water, inert gas in case of dangerous gas 
- Inlet gas consumption: 0%  
- Features: 
  - No inlet gas contamination
  - Independent from inlet flow rate fluctuations 

FCL