Compressed natural gas dryers - CNG dryers
Compressed natural gas dryers (CNG dryers) are designed for continuous separation of water vapour from compressed natural gas thus lowering the dew point.
CNG-DRY dryers are normally custom made to meet specific project requirements. Several versions are available based on operating pressure and type of regeneration.
G-DRY type of the dryers are manual controlled and without regeneration. After the saturation of the dryer it is possible to replace adsorption material or regenerate it with external regeneration system.
CNG-R-DRY has two columns that operate alternately. Adsorption takes place under pressure in the first column while the second column is heat regenerated.
CNG-HP-DRY has also two columns that operate alternately. Regeneration is made by small portion of already dried CNG at the ambient pressure. Purge CNG is let to the suction side of the compressor.
Characteristics of CNG dryers
operating pressure | 0,1-420 bar |
operating temperature (inlet) | 1,5 to 60 °C |
pressure dew point | -40 °C |
flow rate | on request |
design code for pressure vessels | EN 13445 |
fluid group | 1 |
Applications
• CNG applications
• petrochemical
• gas
• gas
Technical data
PRESSURE | REGENERATION TYPE | REGENERATED BY |
---|---|---|
LOW (up to 16 barg) | Heatless regenerated | Expanded Natural gas; Released to torch and/or guided to compressor inlet |
Heat regenerated | Hot natural gas; Released to torch and/or guided to compressor inlet | |
Without regeneration | Replacement of adsorbent or external regeneration unit | |
MEDIUM (up to 50 barg) | Heatless regenerated | Expanded Natural gas; Released to torch and/or guided to compressor inlet |
Heat regenerated | Hot natural gas; Released to torch and/or guided to compressor inlet | |
Without regeneration | Replacement of adsorbent or external regeneration unit | |
HIGH (up to 420 barg) | Heatless regenerated | Expanded Natural gas; Released to torch and/or guided to compressor inlet |
Heat regenerated | Hot natural gas; Released to torch and/or guided to compressor inlet | |
Without regeneration | Replacement of adsorbent or external regeneration unit |
REQUIRED DATA TO PREPARE QUOTATION
• Inlet pressure• Inlet temperature
• Inlet water content
• Preferred dryer type (AUTOMATIC / MANUAL)
• Preferred type of regeneration (HEATLESS / HEAT / REPLACEMENT OF ADSORBENT / EXTERNAL REGENERATION UNIT)
• Availability of water cooling water (YES/NO). If yes temperature of cooling water.
• Possibility to guide regeneration gas to the suction side of the compressor (YES/NO)